UVC Sterilizer UV Light for Drink Water Tank Pool Disinfection
video
UVC Sterilizer UV Light for Drink Water Tank Pool Disinfection

UVC Sterilizer UV Light for Drink Water Tank Pool Disinfection

Stainless steel UVC sterilizer, 99 percent killing rate for the Bacteria in the water, good disinfection solution for the tank and pool

  • Szybka dostawa
  • Zapewnienie jakości
  • Obsługa klienta 24/7
Wprowadzenie produktów

FEATURES

1. Long lifespan

2. Efficient and safe

3. Good reliability and stability

4. Ozone-free

5. Beautiful appearance

6. Large production capacity

7. EPA, ISO9001, CE certified

1

SPECIFICATIONS

1. Type: single stainless steel pipe

2. Peak Wavelength: 254nm

3. Input Voltage: 220vAC

4. Power: 8W-40W

5. Disinfection volume: 0.23-2.7m3

6. Water pressure: 0.6MPa

7. Diameter: 63.5mm

8. Operating Temperature Range: -10 degree - 100 degree

9. Materials: Quartz glass uvc tube, 304/316 stainless steel pipe

10. Lifespan: 10000 hours

2

ADVANTAGE

This series of products is suitable for relatively small areas of water flow, such as household drinkina water, office buildinas, schools, small water tanks, pools and so on.

Single water treatment capacity ranges from {{0}}.2 tons per hour to 3 tons. The cavity is made of 304/316 stainless steel, which conforms to the international standard. Its appearance is beautiful and the quality is guaranteed. The polishing process on the inner wall has improved the sterilization efficiency. Full range of products is 0.6MPa pressure.The diameter of the inlet and outlet can be changed according to the customer's needs.

3


APPLICATIONS

Aquarium disinfection

Water treatment

Water purifier

2

Using methods and management requirements for indoor ultraviolet disinfection lamps

Nowadays, many schools have installed UV disinfection lamps as tools for indoor sterilization. However, it is because of these places, we need to pay attention to the method of use when using the UV disinfection lamp, and strictly abide by relevant management requirements.

1. UV disinfection lamps must be used in indoor unmanned conditions. During the disinfection, the classroom is closed, and non-disinfection prohibits access.

2. When sterilizing with ultraviolet lamp, you must have a warning sign outside the field to remind others that people must not enter and stay.

3. The ultraviolet lamp must be on 5-7 minutes from the light, and the cooling can be moved.

4. When disinfecting, the sterilization object must be fully exposed to ultraviolet rays and achieve sufficient irradiation dose.

5. When a rough surface such as disinfecting paper, the fabric is properly extended, and both sides should be irradiated.

6. The disinfection effect is affected by the ambient temperature, relative humidity, and in air, disinfection targets are affected by organic matter pollution. When sterilizing indoor air, the room must be kept clean, reduce dust and water mist; when the temperature is below 20 degree C or higher than 40 degree C, the relative humidity is greater than 60 percent , or affected by the organic matter, the irradiation time must be appropriately extended.

7. During using the UV lamp, keep the surface clean and dry. Wipe once every 1-2 weeks with alcohol gauze or cotton balls, and find dust, oil, and oil, it is necessary to wipe it at any time.

8. When disinfecting the surface of the object, the surface of the tube should not exceed 1m, and the irradiation time is not less than 30 min in the case where the tube ultraviolet radiation intensity meets the requirements. High strength, low ozone ultraviolet sterilization lamp, irradiated within 30 min to 60 min. The sterilization effective area is 1.5m to 2m around the lamp. When indoor air is disinfected, if the indoor suspended ultraviolet sterilization, the ultraviolet lamp with the reflective cover is mounted in 2m to 2.5m height, and the number of mounting lamps is calculated at no less than 1.5W / m3, and the tube is ultraviolet intensity. In accordance with the requirements, the irradiation time is not less than 30 min.

9. Turn off the ultraviolet light after disinfection, open the doors and windows, and through the full ventilation, the room can be entered.

10. Disinfection should do personal protection to avoid damage to the ultraviolet direct irradiation.

11. UV disinfection must be daily monitoring, daily monitoring includes the starting time of the lamp, accumulated irradiation time, user signature. The new furnish ultraviolet tube irradiation intensity should not be less than 90UW / cm2. The irradiation intensity of the UV lamp must be measured regularly, and the UV tube accumulates for 1000 hours or when the intensity is less than 70UW / cm 2. The ultraviolet light irradiation intensity is used to detect the ultraviolet light irradiation, and the ultraviolet obtrance meter is at least one year.

3

Management requirements

1. UV disinfection lamps(UVC sterilizer UV Light for drink water tank pool disinfection) must be managed, used and registered. Establish ultraviolet use record deskt, record each UV lamp starts using the date, each disinfection time, accumulated disinfection time, disinfection person name, etc.

2. Schools, kindergartens to establish specifications of ultraviolet disinfection lamp operating systems, management systems and emergency plans. Without schools and kindergartens, anyone is not allowed to use ultraviolet sterilization lamps. Once an emergency appears, the emergency plan is immediately started.

Popularne Tagi: UVC sterilizer UV light for drink water tank pool disinfection, China, suppliers, manufacturers, factory, customized, wholesale, bulk, pricelist, in stock, for sale